In this installation, the injection pump is installed in by-pass in order to facilitate the maintenance of the pump without having to cut off the main water supply.
Be careful in this case the water will not be chlorinated anymore
This configuration also allows, if necessary, and if the main water flow is constant, to carry out a partial by-pass which allows only a part of the flow to go through the metering pump.
Upstream of the chemical dosing pump, on the main pipe, a 60 micron filter is installed to protect the dosing pump motor against impurities. After the filter, it is suggested to install a pressure reducer in order to be sure not to exceed the nominal pressure of the pump.
On the pipe, two taps are made, one before the dosing unit which will be used for the preparation of the mother solution. The other tap downstream of the dispenser can be used for testing the dispenser and/or priming it during start-up, during operation, for taking samples and finally, during maintenance, for rinsing the dispenser.
Finally, a non-return valve is required at the end of the dosing line to prevent water from flowing back into the dosing unit, which could in some cases return to the mother solution and dilute it or even cause the container to overflow.
During the installation, the dosing unit must be at a height higher than the mother solution and ideally not above but on the side.